Description
Features
- Heating Cooling Operation
- R410A Refrigerant
- 4 Star Energy Rating
- 3Di-See Sensor*
- Auto Updown Grille*
- Long Life Filter
- Auto Restart
- High Ceiling Mode
- Low Ceiling Mode
- Vector Wave Eco Inverter
- PAM (Pulse Amplitude Modulation)
- DC Fan Motor
- On/Off Operation Timer
- Self Diagnostic
- Easy Installation
- Failure Recall
Technical Specifications
Type (Cooling and Heating)
- Indoor Unit: PLA-RP71EA
- Outdoor Unit: SUZ-KA71VA
- Panel: PLP6EALM-DA
Cooling and Heating Specifications
Guaranteed Operating Range
- Cooling Upper Limit: 46 °CDB
- Cooling Lower Limit: -15 °CDB
- Heating Upper Limit: 24 °CDB
- Heating Lower Limit: -10 °CDB
Rated Operating Conditions
- Cooling – Indoor: 27°C(80°F)DB, 19°C(66°F)WB, Outdoor: 35°C(95°F)DB
- Heating – Indoor: 20°C(68°F)DB, Outdoor: 7°C(45°F)DB, 6°C(43°F)WB
Refrigerant Piping Length (One-way)
7.5m (25ft)
Product image and color shown on the digital platform may appear different than the actual product.
Product specifications & design are subject to change without prior notice for further improvement.
* Optional Features
# BEE star rating is applicable to single-phase machines up to the rated capacity of 10,465 watts.
Performance Parameters | |
---|---|
Cooling | |
Capacity (Min-Max) | 7.1(2.8-8.1) kW |
Capacity | 24,000 BTU/h |
Total Input | 2.1kW |
EER | 3.38 W/W |
ISEER | 4.51 W/W |
Heating | |
Capacity (Min-Max) | 8.0 (2.6-10.2) kW |
Capacity | 27,300 BTU/h |
Total Input | 2.24 kW |
COP | 3.56 W/W |